NOISE-PROTECTION GABIONS
Gabions that are only filled with stones do not provide effective noise protection. To fulfil the noise protection specifications in the relevant standards, it is necessary to install a noise-protection core in the stone basket. The noise-protection core is surrounded by stones and is positioned in the basket so that it cannot be seen. It can be made of various materials. SCHERF performs intensive research in the area of noise-protection with gabions. In recent years we have developed and realised a number of high-quality solutions. Our references include the Austrian highway construction company ASFINAG and the Office of Styrian Government.

Noise protection – basic information
Effective noise control is achieved using a combination of sound damping and sound absorbing measures. The damping indicates the reduction of the noise level when passing through a noise-protection element. The sound absorption is the proportion of sound that is „swallowed“ by the noise-protection element and therefore cannot be reflected (noise protection for the area across from the noise-protection wall). A sound reduction of 10 dB is perceived as halving the noise level.
More information about the noise protection can be found at www.asfinag.at and www.verkehr.steiermark.at.
Noise protection
Classification of the sound absorption according to EN 1793-1
| Group | DLa [dB] |
|---|---|
| A0 | Not tested |
| A1 | < 4 |
| A2 | 4 to 7 |
| A3 | 8 to 11 |
| A4 | > 11 |
Classification of the sound insulation according to EN 1793-2
| Group | DLα [dB] |
|---|---|
| B0 | Not tested |
| B1 | < 15 |
| B2 | 15 to 24 |
| B3 | > 24 |
DLα [dB] = noice reduction in dB
Noise protection
Our systems are suitable for noise-protection measures by highways, streets, train tracks, in residential areas, industrial zones and other noisy areas. Various fill materials are available (see page 62). The variety of rocks and colours makes it possible to use natural stones typical to the region.
Highly absorbent noise barriers can be constructed using open-pore lava as a filling material (group A3 under EN1793-1).
The noise seal of the joints between the baskets is of particular importance. Our innovative joint seal system prevents the transmission of sound. The systems were tested for noise properties by accredited testing institutes. The measurements were performed on continuous walls (including joints).
Test certificates can be provided upon request. Our task is to find a suitable solution for the given situation. Noise-protection projects require exact planning and project management (dimensioning, statics, available space, optic, visual impact). Upon request we can provide project-based concepts, offers and tender specifications.
Prefabricated gabion with noise-protection core
- No deep foundation required
- Fast construction
- Project-related wall depth – dependent on wall height, wind load and project size
- Can also be used as a column for noise-protection elements made out of other materials (wood concrete, wood, glass, aluminium). The wind loads are absorbed by the stone basket. Compared to other column solutions, no expensive deep foundation is necessary here.
- Classification according to EN 1793: absorption A2 or A3, damping B3
DIY gabion with noise insulation kit
- Available at wall depths of 30 cm and 50 cm
- No deep foundation necessary
- Simple construction
- Perfect for DIY enthusiasts
- Classification according to EN 1793: absorption A1 (with lava filling material A3), damping B3
Noise-protection cassette for insertion into HEA steel columns
- Narrow construction – very small footprint (depth 18.5 cm or 25 cm)
- Wall depth 18.5 cm: Mesh size 5x20 cm, One side natural stone filling, Back side, e.g. wood decor
- Wall depth 25 cm: Mesh size 2.5x20 cm, Both sides natural stone filling
- Steel columns must have a deep foundation
- Prefabricated elements produced in the factory
- Construction similar to familiar noise-protection systems made of wood, aluminium or wood concrete
- Combinations possible with elements of the specified materials
- Classification according to EN 1793: absorption A2 or A3, damping B3